We are Manufacturer and Supplier of Optical Accessories
₹ 35 / Piece Get Latest Price
| Connector Type | SC to SC |
| Fiber Mode | Single Mode |
| Cable Length | 5 m |
| Material | Fiber Patch Cord SC APC |
| Color | Yellow wire with Green connector |
| Fiber Count | 1 Core |
| Jacket Material | PVC |
| Brand | Optivision |
| Type | FIBER PATCH CORD |
| Fiber Optic Patchcord Type | Single Mode |
| Usage/Application | Broadband Network |
| Fibre Diameter | 5m |
| Cable Color | Yellow |
| Polish Type | UPC |
| Cable Diameter | 3 mm |
| Standards | TIA/EIA 568 |
| Usage | Fiber optic data transmission |
Minimum order quantity: 50 Piece
The Optical Fiber Patch Cord SC/UPC is a factory-terminated fiber optic cable assembly equipped with SC/UPC (Ultra Physical Contact) connectors on one or both ends. It is designed for reliable optical signal transmission in telecommunications networks, data centers, FTTH deployments, and optical distribution systems.
The SC/UPC connector provides low insertion loss and moderate return loss, suitable for most general-purpose single-mode and multimode applications.
2. Standards ComplianceThe patch cord shall comply with the following standards:IEC 61754-4 (SC connector interface standard)
IEC 61755-3-1 (UPC connector performance standard)
ITU-T G.652.D / G.657 (for single-mode fiber)
| Parameter | Specification |
|---|---|
| Connector Type | SC/UPC |
| Ferrule Material | Zirconia ceramic |
| Ferrule End Face | Ultra Physical Contact (Flat polish) |
| Ferrule Diameter | 2.5 mm |
| Connector Color | Blue (UPC standard) |
| Boot Type | Standard / Short boot (optional) |
| Parameter | Typical Value | Maximum Value |
|---|---|---|
| Insertion Loss (IL) | ≤ 0.20 dB | ≤ 0.30 dB |
| Return Loss (RL) | ≥ 50 dB | — |
| Operating Wavelength | 1310 nm / 1550 nm | |
| Fiber Standard | ITU-T G.652.D / G.657.A1 / G.657.A2 |
| Parameter | Specification |
|---|---|
| Cable Structure | Simplex / Duplex |
| Cable Diameter | 2.0 mm / 3.0 mm (standard) |
| Jacket Material | LSZH / PVC |
| Tensile Strength (Short Term) | ≥ 90 N |
| Tensile Strength (Long Term) | ≥ 70 N |
| Minimum Bend Radius (Static) | ≥ 10 × cable diameter |
| Minimum Bend Radius (Dynamic) | ≥ 20 × cable diameter |
| Mating Durability | ≥ 1000 cycles |
| Connector Retention Force | ≥ 50 N |
| Parameter | Specification |
|---|---|
| Operating Temperature | -20°C to +70°C |
| Storage Temperature | -40°C to +80°C |
| Relative Humidity | ≤ 95% (non-condensing) |
100% factory tested for insertion loss and return loss
End-face geometry inspected
Visual inspection under 400x microscope
FTTH (Fiber to the Home)
LAN/WAN networks
Data centers
Optical Distribution Frames (ODF)
Telecommunication backbone systems
Patch panels and fiber management systems
SC/UPC to SC/UPC
SC/UPC to LC/UPC
SC/UPC to ST/UPC
SC/UPC to FC/UPC
Standard lengths: 1m, 2m, 3m, 5m, 10m, 15m, 20m
₹ 35 / Piece Get Latest Price
| Category | Fiber Optic |
| Length | 5 m |
| Mode Type | Single Mode |
| Fiber Mode | Single Mode |
| Material | PVC |
| Color | Yellow |
| Shielding Type | UTP |
| Jacket Material | PVC |
| Brand | Optivision |
| Type | FIBER PATCH CORD |
| Connectors | SC APC |
| Usage/Application | Broadband Network |
| Polish Type | APC |
| Wire Size | 5m |
| Conductor Type | Stranded |
| Connector Type | SC-APC |
| Fibre Core | Simplex |
| Fiber Optic Patchcord Type | Single Mode |
| Fibre Diameter | 3mm |
| Usage | CATV Network |
Minimum order quantity: 50 Piece
The Optical Fiber Patch Cord SC/APC is a factory-terminated fiber optic cable assembly with SC/APC (Angled Physical Contact) connectors on one or both ends. It is designed for high-performance optical transmission systems requiring low insertion loss and high return loss, particularly in FTTH, CATV, PON, and telecommunications networks.
The patch cord shall comply with the following standards:
IEC 61754-4 (SC connector interface standard)
IEC 61755-3-2 (APC connector performance standard)
IEC 61300 (fiber optic interconnecting devices testing procedures)
RoHS compliant materials
| Parameter | Specification |
|---|---|
| Connector Type | SC/APC |
| Ferrule Material | Zirconia ceramic |
| Ferrule End Face | 8° angled (APC) |
| Ferrule Diameter | 2.5 mm |
| Connector Color | Green (APC standard) |
| Polishing Type | Angled Physical Contact |
| Parameter | Typical Value | Maximum Value |
|---|---|---|
| Insertion Loss (IL) | ≤ 0.20 dB | ≤ 0.30 dB |
| Return Loss (RL) | ≥ 60 dB | — |
| Operating Wavelength | 1310 nm / 1550 nm | |
| Fiber Type | G.652.D / G.657.A1/A2 |
| Parameter | Typical Value | Maximum Value |
|---|---|---|
| Insertion Loss | ≤ 0.20 dB | ≤ 0.30 dB |
| Return Loss | ≥ 35 dB | — |
5. Mechanical Characteristics
| Parameter | Specification |
|---|---|
| Cable Diameter | 2.0 mm / 3.0 mm (standard) |
| Cable Type | Simplex / Duplex |
| Jacket Material | LSZH / PVC |
| Tensile Strength (Short Term) | ≥ 90 N |
| Tensile Strength (Long Term) | ≥ 70 N |
| Minimum Bend Radius (Static) | ≥ 10 × cable diameter |
| Minimum Bend Radius (Dynamic) | ≥ 20 × cable diameter |
| Durability | ≥ 1000 mating cycles |
| Connector Retention Force | ≥ 50 N |
| Parameter | Specification |
|---|---|
| Operating Temperature | -20°C to +70°C |
| Storage Temperature | -40°C to +80°C |
| Relative Humidity | ≤ 95% (non-condensing) |
FTTH (Fiber to the Home)
GPON / EPON networks
CATV distribution systems
Telecommunication network
₹ 75 / Piece Get Latest Price
| Split ratio | 1x2 |
| Package type | Steel tube |
| Material | Fiber |
| Wavelength range | 1260–1650 nm |
| Input fiber length | 1 m |
| Usage/Application | CATV & NETWORKING |
| Fiber Type | yes |
| Packaging Size | 100pcs Packing |
| Cable Diameter | 250um |
| Color | WHITE |
| Operating temp | -40 to 85 C |
| Insertion loss | ≤3.8 dB |
| Brand | OPTIVISION |
| Operating Temperature | -40-85 deg C |
| Connector Type | No Connector |
Minimum order quantity: 50 Piece
The PLC Splitter 1×2 is a passive optical power management device based on Planar Lightwave Circuit (PLC) technology. It is designed to split one optical input signal into two equal output signals with uniform power distribution.
The splitter is suitable for use in PON networks (GPON/EPON), FTTH deployments, CATV systems, and optical distribution networks.
The PLC splitter shall comply with the following standards:
ITU-T G.657 / G.652 (fiber standard)
IEC 61300 (fiber optic interconnecting devices and passive components – test procedures)
Telcordia GR-1209-CORE
Telcordia GR-1221-CORE
RoHS compliant
| Parameter | Specification |
|---|---|
| Split Ratio | 1 × 2 |
| Input Ports | 1 |
| Output Ports | 2 |
| Technology | Planar Lightwave Circuit (PLC) |
| Fiber Type | Single Mode 9/125 µm |
| Operating Wavelength | 1260 – 1650 nm |
| Parameter | Typical Value | Maximum Value |
|---|---|---|
| Insertion Loss | 3.6 dB | ≤ 4.0 dB |
| Uniformity | ≤ 0.5 dB | ≤ 0.8 dB |
| Return Loss | ≥ 55 dB | |
| Directivity | ≥ 55 dB | |
| Polarization Dependent Loss (PDL) | ≤ 0.2 dB | ≤ 0.3 dB |
| Wavelength Dependent Loss (WDL) | ≤ 0.3 dB | ≤ 0.5 dB |
| Parameter | Specification |
|---|---|
| Packaging Type | Bare Fiber / Mini Module / ABS Box / LGX Cassette |
| Fiber Length | 1.0 m (standard) or customized |
| Connector Type | SC/UPC, SC/APC, LC/UPC (optional) |
| Connector Return Loss | ≥ 50 dB (UPC), ≥ 60 dB (APC) |
| Fiber Jacket | 250 µm / 900 µm / 2.0 mm / 3.0 mm |
| Cable Color | As per standard or customer requirement |
| Parameter | Specification |
|---|---|
| Operating Temperature | -40°C to +85°C |
| Storage Temperature | -40°C to +85°C |
| Operating Humidity | ≤ 95% (non-condensing) |
Fully passive device (no power required)
High stability across full wavelength range
Low temperature sensitivity
Designed for long-term outdoor and indoor use
Compliant with Telcordia reliability standards
FTTH (Fiber to the Home)
GPON / EPON networks
Passive Optical Networks (PON)
Optical Distribution Frames (ODF)
CATV optical distribution
Data communication networks
Input (1 fiber) → PLC chip → 2 equal output fibers (50% optical power each)
₹ 90 / Piece Get Latest Price
| Split ratio | 1x4 |
| Connector type | No connector |
| Package type | Steel tube |
| Material | Fiber |
| Wavelength range | 1260–1650 nm |
| Fiber type | G652D |
| Input fiber length | 1 m |
| Usage/Application | CATV & NETWORKING |
| Packaging Size | 100pcs Packing |
| Cable diameter | 0.9 mm |
| Operating temp | -40 to 85 C |
| Insertion loss | ≤7.2 dB |
| Brand | OPTIVISION |
Minimum order quantity: 50 Piece
The PLC Splitter 1×4 is a passive optical power distribution device based on Planar Lightwave Circuit (PLC) technology. It divides one optical input signal into four equal output signals with uniform power distribution across all output ports.
The device is designed for high-reliability optical distribution in Passive Optical Networks (PON), FTTH systems, CATV networks, and telecommunication infrastructure.
The splitter shall comply with:
ITU-T G.652.D / G.657.A1 / G.657.A2 (Single-mode fiber standards)
IEC 61300 (Fiber optic passive component test procedures)
Telcordia GR-1209-CORE
Telcordia GR-1221-CORE
RoHS compliant
| Parameter | Specification |
|---|---|
| Split Ratio | 1 × 4 |
| Input Ports | 1 |
| Output Ports | 4 |
| Technology | Planar Lightwave Circuit (PLC) |
| Fiber Type | Single Mode 9/125 µm |
| Operating Wavelength | 1260 – 1650 nm |
| Parameter | Typical Value | Maximum Value |
|---|---|---|
| Insertion Loss | 7.0 dB | ≤ 7.4 dB |
| Uniformity | ≤ 0.6 dB | ≤ 1.0 dB |
| Return Loss | ≥ 55 dB | |
| Directivity | ≥ 55 dB | |
| Polarization Dependent Loss (PDL) | ≤ 0.2 dB | ≤ 0.3 dB |
| Wavelength Dependent Loss (WDL) | ≤ 0.3 dB | ≤ 0.5 dB |
| Parameter | Specification |
|---|---|
| Packaging Type | Bare Fiber / Mini Module / ABS Box / LGX Cassette |
| Fiber Length | 1.0 m (standard) or customized |
| Connector Type | SC/UPC, SC/APC, LC/UPC (optional) |
| Connector RL | ≥ 50 dB (UPC), ≥ 60 dB (APC) |
| Fiber Jacket Options | 250 µm / 900 µm / 2.0 mm / 3.0 mm |
| Cable Color | Standard or customized |
| Parameter | Specification |
|---|---|
| Operating Temperature | -40°C to +85°C |
| Storage Temperature | -40°C to +85°C |
| Relative Humidity | ≤ 95% (non-condensing) |
FTTH (Fiber to the Home)
GPON / EPON systems
Optical Distribution Networks (ODN)
Optical Distribution Frames (ODF)
CATV optical networks
Telecommunication backbone systems
100% factory tested before shipment
Individual insertion loss measurement
End-face inspection (if connectorized)
Serial number traceability (optional)
₹ 75 / Piece Get Latest Price
| Coupler type | 1x2 |
| Connector type | No connector |
| Fiber type | G652D |
| Split ratio | 50:50 |
| Wavelength | 1310/1550 nm |
| Package type | Steel tube |
| Insertion loss | ≤3.5 dB |
| Cable diameter | 0.9 mm |
| Operating temp | -40 to 85 C |
Minimum order quantity: 50 Piece
In FBT technology:
Two (or more) fibers are aligned and twisted together.
The fibers are heated using a flame, filament, or CO₂ laser.
The softened region is stretched to form a biconical taper.
Optical coupling occurs in the tapered waist due to overlapping evanescent fields.
The coupling ratio is determined by:
Taper length
Taper diameter
Fusion temperature profile
Pulling speed
Wavelength dependency of mode propagation
Because FBT couplers are wavelength-sensitive, triple window designs require careful process optimization to balance coupling ratios across all three operating wavelengths.
Typical parameters include:
Configuration: 1×2, 2×2, or multiport
Operating Wavelengths: 850 / 1310 / 1550 nm
Split Ratios: Custom (e.g., 50:50, 70:30, 90:10, or asymmetric)
Insertion Loss: ≤ 3.5 dB (50:50 type typical)
Excess Loss: ≤ 0.2–0.5 dB
Polarization Dependent Loss (PDL): ≤ 0.1 dB (typical)
Return Loss: ≥ 50 dB
Operating Temperature: −40°C to +85°C
Fiber Type: Single-mode (e.g., G.652) or multimode
Packaging: Steel tube, ABS module, or LGX cassette
Unlike planar lightwave circuit (PLC) splitters, FBT couplers exhibit wavelength-dependent coupling behavior. In triple window designs, the coupling ratio is specified separately for each wavelength band to ensure controlled performance variation.
Environmental StabilityProper packaging ensures:
Mechanical stability
Thermal stability
Long-term reliability
Low aging drift
FBT couplers are generally more cost-effective than PLC splitters for:
Low port-count applications
Custom split ratios
Short-distance networks
Optical signal distribution
CATV networks
Fiber optic sensing systems
Local area networks (LAN)
Test and measurement systems
Redundant optical path systems
Customizable split ratios
Low excess loss
Simple fabrication process
Suitable for small splitting configurations
Cost-effective for non-uniform splitting
₹ 0.45 / Piece Get Latest Price
| Sleeve Length | 60 mm |
| Cable Diameter | 3 mm |
| Tube Material | Polyolefin |
| Rod Material | Stainless Steel |
| Operating Temp | -40 to 85°C |
| Color | Clear |
| Compliance | RoHS |
| Packing | Zip Bag |
| Fiber Type | Single Fiber |
Minimum order quantity: 2000 Piece
A fiber protection sleeve (also called a heat-shrink splice protection sleeve) is a mechanical reinforcement device designed to protect fusion-spliced optical fibers from mechanical stress, moisture ingress, and environmental exposure. It provides strain relief and restores tensile strength at the splice point.
A standard fiber protection sleeve consists of three main components:
Outer Heat-Shrink Tube
Material: Polyolefin (cross-linked)
Function: Environmental sealing and mechanical protection
Strength Member
Material: Stainless steel rod or ceramic rod
Function: Reinforces the splice area and prevents bending stress
Inner Adhesive Tube
Material: EVA (Ethylene Vinyl Acetate) or hot-melt adhesive
Function: Bonds to fiber coating during heating to seal against moisture and contaminants
| Parameter | Typical Value |
|---|---|
| Length (standard) | 40 mm / 45 mm / 60 mm |
| Outer Diameter (before shrink) | 2.5 – 3.0 mm |
| Outer Diameter (after shrink) | 1.8 – 2.2 mm |
| Strength Member Diameter | 1.0 – 1.5 mm |
| Tensile Strength | ≥ 10 N |
| Shrink Ratio | ≥ 2:1 |
| Splice Protection Type | Single fiber |
Micro sleeves (for high-density trays) typically have 1.2–1.5 mm final outer diameter.
Shrink Temperature: 110°C – 130°C
Full Recovery Time: 30 – 60 seconds (depending on heater type)
Operating Temperature Range: −40°C to +85°C
Storage Temperature: −40°C to +85°C
No measurable additional insertion loss after proper installation
No induced back reflection
Compatible with single-mode and multimode fibers
Suitable for G.652, G.657, and multimode fiber types
Moisture-resistant sealing
Resistant to vibration and mechanical shock
Compliant with RoHS environmental standards
UV-resistant (for outdoor applications)
Typical compliance with:
IEC 61753 (fiber optic interconnecting devices performance standard)
Telcordia GR-1380 (generic requirements for splice protectors)
RoHS Directive
Fiber optic fusion splice protection
FTTH networks
Telecommunications backbone systems
CATV networks
Data centers
Industrial fiber installations
₹ 105 / Piece Get Latest Price
| Material | Fiber |
| Usage/Application | CATV & NETWORKING |
| Fiber Type | yes |
| Packaging Size | 100pcs Packing |
| Color | WHITE |
| Cable Diameter | 250um |
| Operating Temperature | -40-85 deg C |
| Brand | OPTIVISION |
| Connector Type | No Connector |
Minimum order quantity: 50 Piece
The PLC Splitter 1×8 is a passive optical power distribution component based on Planar Lightwave Circuit (PLC) technology. It divides one optical input signal into eight equal output signals with uniform power distribution and low insertion loss.
The splitter is designed for use in Passive Optical Networks (PON), FTTH systems, CATV distribution, and telecommunication networks requiring stable and reliable signal splitting over a wide wavelength range.
The PLC splitter shall comply with the following standards:
ITU-T G.652.D / G.657.A1 / G.657.A2
IEC 61300 (Fiber optic passive component testing procedures)
Telcordia GR-1209-CORE
Telcordia GR-1221-CORE
RoHS compliant
| Parameter | Specification |
|---|---|
| Split Ratio | 1 × 8 |
| Input Ports | 1 |
| Output Ports | 8 |
| Technology | Planar Lightwave Circuit (PLC) |
| Fiber Type | Single Mode 9/125 µm |
| Operating Wavelength | 1260 – 1650 nm |
| Parameter | Typical Value | Maximum Value |
|---|---|---|
| Insertion Loss | 10.2 dB | ≤ 10.7 dB |
| Uniformity | ≤ 0.8 dB | ≤ 1.5 dB |
| Return Loss | ≥ 55 dB | |
| Directivity | ≥ 55 dB | |
| Polarization Dependent Loss (PDL) | ≤ 0.2 dB | ≤ 0.3 dB |
| Wavelength Dependent Loss (WDL) | ≤ 0.3 dB | ≤ 0.5 dB |
| Parameter | Specification |
|---|---|
| Packaging Type | Bare Fiber / Mini Module / ABS Box / LGX Cassette |
| Fiber Length | 1.0 m (standard) or customized |
| Connector Options | SC/UPC, SC/APC, LC/UPC |
| Connector Return Loss | ≥ 50 dB (UPC), ≥ 60 dB (APC) |
| Fiber Jacket | 250 µm / 900 µm / 2.0 mm / 3.0 mm |
| Cable Color | Standard or custom |
| Parameter | Specification |
|---|---|
| Operating Temperature | -40°C to +85°C |
| Storage Temperature | -40°C to +85°C |
| Humidity | ≤ 95% (non-condensing) |
Fully passive device (no electrical power required)
High reliability and stability over full wavelength range
Low temperature sensitivity
Designed for indoor and outdoor deployment
Expected operational life ≥ 20 years under standard conditions
FTTH (Fiber to the Home)
GPON / EPON systems
Optical Distribution Network (ODN)
CATV optical transmission systems
Telecommunication backbone networks
100% factory tested for insertion loss and uniformity
Individual port measure
Aman Singhal (Managing Director)
Mohan Electronics & Systems
No. 571, Street No. 6
New Delhi - 110093, Delhi, India